"DC=Double Controller" is in fact two temperature controllers placed in one housing with the possibility of any configuration of inputs and outputs and linking both controllers. The device has 2 inputs and 2 control outputs that can operate in heating or cooling mode. Installation in an electrical switchboard on a DIN TH-35 rail.
Entry: | 2 NTC temperature sensors 5kOhm at 25°C digital input (standard open or closed) |
Measurement range: | -50 ... + 150°C |
Measurement Accuracy: | +/- 0.5°C |
Sampling period: | 330 ms |
Indication resolution: | 0.1°C over the entire range |
Setting resolution: | 0.1°C over the entire range |
Display: | LED, 4 digits 11mm high with graphic icons |
Adjustment method: | ON-OFF with hysteresis |
Adjustment Accuracy: | adjustable in the range of 0.1 ... 20.0°C |
Control outputs: | 1 relay 20A 4.5kW, durability 100 thousand. cycles 1 relay 8A 1.5kW, durability 100 thousand. cycles |
Additional features: | - mathematical functions (difference, average measurement) - selection of the temperature channel for reading - sound signaling of alarm states - possibility of linking both measurement outputs (linking their operation) |
Installation: | on DIN TH-35 rail |
Degree and protection class: | IP20 /II |
Power: | 230VAC +/- 15% or 12VAC/DC or 24AC/DC |
Power consumption: | 3VA max |
Working conditions: | -5 ... 60°C; 0 ... 85% RH (non-condensing) |
Storage conditions: | -40 ... 85°C; 0 ... 85% RH (non-condensing) |
Application:
and cooling:
If you do not know which regulator to choose, please read the article.
Basic information:
The regulator has a digital temperature readout and the function of calibration of indications. The value from sensor T1 and T2 is displayed alternately every 3 seconds. You can set the controller to display only one reading.
The built-in sounder can be set to signal activation of outputs and alarm states.
The digital input can function as an alarm input or a manual output control mode. It can signal a system failure after the activation of an external pressure switch or STB temperature limiter connected to the digital input. In the event of a failure, it will disconnect the entire system with the ability to maintain the failure state until manually reset by pressing the button.
The regulator is equipped with a high-power relay output 1 20A (maximum resistive load 4500W) and Output 2 with a maximum load of 8A. Installation in an electrical switchboard on a DIN TH-35 rail.
range: -50 ... + 150 ° C,
input: NTC 5kΩ at 25 ° C
regulation: basic
outputs: 2