CO-10 temperature controller with LED display for automatic activation of the central heating circulation pump. When the temperature reaches the set value, the regulator starts the circulation pump and turns it off only when the boiler cools down to the set low temperature.
Power: | 230VAC +/- 15% |
Setting range: | 10 ... + 80 ° C |
Hysteresis: | 0.1 ... 20.0 ° C |
Fuse link: | 2.5A |
Measurement Accuracy: | +/- 0.5°C |
Indication resolution: | 0.1°C over the entire range |
Sensor length: | 3.0 running meters |
Setting resolution: | 0.1°C over the entire range |
Display: | LED, 4 digits 14mm high with graphic icons |
Maximum pump load: | 2.5A |
Additional features: | - MIN and MAX temperature alarm - sound signaling of temperature alarm and sensor failure - MAX/MIN memory |
Installation: | wall |
Degree and protection class: | IP40 /II |
Power consumption: | max. 3VA |
Working conditions: | -5 ... 60 ° C; 0 ... 85% RH (non-condensing) |
Storage conditions: | -40 ... 85 ° C; 0 ... 85% RH (non-condensing) |
Functions performed by the controller:
The use of the CO-10 regulator allows you to turn off the circulation pump when the water temperature is insufficient for efficient heating of the rooms. Thanks to this action, we prevent unnecessary operation of the pump, save electricity, and extend the life of the pump. The CO-10 regulator also has the ANTI-STOP function that prevents the circulation pump from stagnating in the off-season, the pump starts every 10 days for 1 minute.
Additional features:
range: -40 .. + 105 ° C
item: NTC 5kΩ
dimensions: 6x50mm
cable: 2m, 5m, 10m, PVC, 2 cores
© ESCO S.C 2024